Kajian kenyamanan visual pada gedung perpustakaan ditinjau dari nilai intensitas cahaya dalam ruangan
Sativa Sativa, Universitas Negeri Yogyakarta, Indonesia
Abstract
Study of visual comfort in the library building based on the value of light intensity inside the room
This study aimed to assess the adequacy of light intensity levels in the Sragen District Library building against the standards set by SNI 03–6197–2011. The observation process began with a review of relevant lighting theories, followed by an assessment of the library spaces, field testing involving the measurement of room dimensions, and light intensity readings. The library was divided into three zones: storage, reading, and circulation. Measurement points within these zones were determined based on SNI 16–7062–2004, and light intensity was measured using a luxmeter. The results indicate that the area of openings in the building is 27.3%, which is outside the ideal range specified by SNI (10%-20%). The average light intensity in the circulation zone at 08:30 WIB is 958 Lux, while at 10:30 and 12:30 WIB, it is 118 Lux and 67 Lux, respectively. In the reading zone, the average light intensity at 08:30, 10:30, and 12:30 WIB is 218 Lux, 207 Lux, and 202 Lux, respectively. For the storage zone, the average light intensity at 08:30, 10:30, and 12:30 WIB is 119 Lux, 78 Lux, and 77 Lux, respectively. Observations reveal that none of the measured values meet the SNI standard of 300 Lux.
Keywords
Full Text:
PDFReferences
Badan Standarisasi Nasional. (2001). SNI 03-2396-2001 tata cara perancangan sistem pencahayaan alami pada bangunan gedung. BSN.
Badan Standarisasi Nasional. (2004). SNI 16–7062–2004 pengukuran intensitas penerangan di tempat kerja. BSN.
Badan Standarisasi Nasional. (2011). SNI 6197–2011 konservasi energi pada sistem pencahayaan. BSN.
Budhiyanto, A., & Chiou, Y. S. (2024). Visual comfort and energy savings in classrooms using surveillance camera derived HDR images for lighting and daylighting control system. Journal of Building Engineering, 86, 108841.
Manurung, P. (2012). Pencahayaan alami dalam arsitektur. ANDI Yogyakarta
Michel, L. (1966). Light: The shape of space. Designing with space and light. John Wiley & Sons, Inc.
Mumpuni, P. W. (2017). Pencahayaan alami pada ruang baca perpustakaan umum Kota Surabaya. Vitruvian: Jurnal Arsitektur, Bangunan, dan Lingkungan, 6, 71-78. Retrieved from https://publikasi.mercubuana.ac.id/index.php/virtuvian/article/view/1403.
Padmanaba, Cok Gd Rai. (2006). Pengaruh penerangan dalam ruang terhadap produktivitas kerja mahasiswa desain interior. Dimensi Interior, 4(2), 57-63.
Qu, G., Ren, L., Liu, G., Zhang, Y., Lau, S. K., Zhan, M., & Yan, M. (2024). The best college classroom light environments have changed: Attributed to the public health issue of decreased sensitivity to students’ eyesight. Energy and Buildings, 307, 113948.
DOI: https://doi.org/10.21831/jps.v1i1.72245
Refbacks
- There are currently no refbacks.
Copyright (c) 2024 Jurnal Penelitian Saintek
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.
p-ISSN: 1412-3991 || e-ISSN: 2528-7036
Indexed by:
View My Stats