POTENTIOMETRIC BASED LEAD SENSOR TO DETECT THE LEVELS OF LEAD IN BLOOD

Eka Novitasari, Brawijaya University, Indonesia
Ayu Rahayu Anggraeni, Brawijaya University
- Muhiroh, Brawijaya University
Mokhammad W. Dahlan, Brawijaya University
Ani Mulyasuryani, Brawijaya University, Indonesia

Abstract


This study was aimed at determining the optimal conditions of lead sensor in the development of ion lead sensor to perform the optimization of several parameters such as the number of ionophores and membrane thickness. In this study, a lead sensor based on lead selective electrode was developed. The electrode was modifi ed by adding lead sulfi de in chitosan membran as an active agent (ionophores) and superimposed on the surface of SPCE. The amounts of PbS added in chitosan solution were 0.5%, 1%, 1.5%, 2%, and 2.5% (w/v). The thickness of membrane used were 15 µm, 20 µm, 45 µm, and 75 µm. The sensors were tested in  standard solution at concentration 10 -8  M to 10  M and at pH 2, 3, 4, and 5. Lead sensor has optimum performance on PbS 1.5%, thickness of membrane on 15 µm and pH 4. The Nernst factor obtained was 23.45 mV/decade with the solution concentration range 0.032 ppm to 0.322 ppm.-1


Keywords


Lead in blood; lead sensor; lead sulfi de

Full Text:

PDF

References


Aini, Z. (2016). Pengaruh ketebalan membran kitosan terhadap kinerja sensor fenol potensiometri berbasis Screen Printed Carbon Electrode (SPCE) (Skripsi).

Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Brawijaya, Malang. Bühlman, P., & Chen, L. D. (2012). Supramolecular chemistry: From molecules to nanomaterials. USA: JohnWiley and Sons.

Ceresa, A. (2001). Ion-selective polymeric membrane electrodes for potentiometrie trace level measurements (Doctoral Dissertation). Swiss Federal Institute of Technology Zurich, Swiss.

Ghaedi, M., Montazerozohori, M., Andikaey, Z., Shokrollahi, A., Khodadoust, S., Behfar, M., & Sharifi , S. (2011). Fabrication of Pb2+ Ion Selective Electrode Based on 1-((3-((2-Hydroxynaphthalen1-yl)Methyleneamino)-2,2Dimethylpropylimino)Methyl) Naphthalen-2-ol as New Neutral 53 54 Ionophore. International Journal of Electrochemical Science, 6, pp. 41274140.

Mifbakhuddin. (2007). Hubungan kadar Pb dalam darah dengan profi l darah pada petugas operator stasiun pengisian bahan bakar umum di Daerah Kota Semarang Timur. Jurnal Kesehatan Masyarakat Indonesia, 4(2), 51-60.

Mulyasuryani, A., Sabarudin, A., & Suryantoro, A. (2014). Pengaruh konsentrasi cetyltrimethylammonium benzoat dan pH larutan terhadap kinerja elektroda selektif ion benzoat berbasis screen printed carbon electrode. Kimia

Student Journal, 2(1), 313-319. Oxtoby, D. W. (2001). Prinsip-prinsip dasar kimia modern. Jakarta: Erlangga.

Primaharinastiti, R. (2012). Pembuatan dan karakterisasi elektrode selektif ion(ESI) salbutamol berbasis membran tipe kawat terlapis. Berkala Ilmiah Kimia Farmasi, 1(1).

Rosemiyani, I. (2013). Pengaruh pH dan ion asing terhadap kinerja elektroda selektif ion (ESI) timbal (II) tipe kawat terlapis unutk menen tukan kandungan timbal dalam Kosmetik (Skripsi). Universitas Brawijaya, Malang.

Sari, D. P. (2010). Pengaruh konsentrasi Ba(IO 3 ) dan ketebalan membran kitosan terhadap kinerja elektroda selektif ion (ESI) iodat (Skripsi). Universitas Brawijaya, Malang. 2

Suherni. (2010). Keracunan timbal di Indonesia (Thesis). Macquarie University, Sydney, Australia.

Wang, J. (2006). Analytical electrochemistry (3 rd ed.). Hoboken: Wiley-VCH.