Non-Invasive Device for Cholesterol, Uric Acid, and Glucose Monitoring: Implementation of Moving Average Filter
DOI:
https://doi.org/10.21831/jraee.v3i1.1012Keywords:
Programmable logic controller, SCADA, Water treatment automation, Human-machine interface, Chlorine dosingAbstract
Early detection is crucial in preventing diseases caused by high blood glucose, cholesterol, and uric acid levels through routine examinations. However, current testing devices are invasive, uncomfortable, complex, and generate medical waste. Therefore, this study aimed to develop and design a non-invasive measurement tool for these three parameters using the MAX30102 sensor. This research applied the Research and Development (R&D) method using the ADDIE model, adapted to the laboratory testing stage. The infrared values measured by the MAX30102 sensor on the fingertip were converted into mg/dL for blood glucose, cholesterol, and uric acid using a linear regression method to form regression equations. The converted data were then compared with standard devices to assess their accuracy. Additionally, a moving average filter was applied to reduce noise, smooth the signal, and balance the response to data changes. The measurement results were displayed on an OLED screen, a smartphone application for monitoring history and providing health information, and a speaker announcing the result categories. The results of the study showed that the cholesterol measurement accuracy was 89.71%, with an error rate of 10.29%, the uric acid accuracy was 92.98%, with an error rate of 7.02%, and the blood glucose accuracy was 92.64%, with an error rate of 7.36%.
Downloads
References
[1] Tim Promkes RSST, “Penyakit tidak menular (PTM),” Kementerian Kesehatan Republik Indonesia, Jul. 31, 2022. [Online]. Available: Kementerian Kesehatan RI – Penyakit Tidak Menular (PTM).
[2] Amila, E. Sembiring, and N. Aryani, “Deteksi dini dan pencegahan penyakit degeneratif pada masyarakat wilayah Mutiara Home Care,” Jurnal Kreativitas Pengabdian Kepada Masyarakat (PKM), vol. 4, no. 1, pp. 102–112, 2021, doi: 10.33024/jkpm.v4i1.3441.
[3] M. R. Kurniawan and A. Humaedi, “Gambaran kesehatan glukosa darah, kolesterol dan asam urat pada guru dan karyawan SDN Cawang,” JPKMI (Jurnal Pengabdian Kepada Masyarakat Indonesia), vol. 1, no. 3, pp. 176–185, 2020, doi: 10.36596/jpkmi.v1i3.70.
[4] Badan Penelitian dan Pengembangan Kesehatan, Laporan Nasional Riskesdas 2018. Jakarta, Indonesia: Lembaga Penerbit Badan Penelitian dan Pengembangan Kesehatan, 2019.
[5] N. Yuniar, “Rancang bangun alat deteksi kadar kolesterol dalam darah dengan teknik non-invasive berbasis mikrokontroler Wemos D1 R1,” undergraduate thesis, Fakultas Matematika dan Ilmu Pengetahuan Alam, Universitas Lampung, Bandar Lampung, Indonesia, 2023.
[6] D. Sutarya, “Sistem monitoring kadar gula darah, kolestrol dan asam urat secara non-invasive menggunakan sensor GY-MAX 30100,” JOULE: Jurnal Ilmiah Teknologi Energi, Teknologi Media Komunikasi dan Instrumentasi Kendali, vol. 1, no. 1, pp. 25–34, 2021.
[7] B. Julia, “Desain dan pengembangan alat ukur kadar hemoglobin dalam darah secara non-invasive menggunakan sensor TCRT5000 berdasarkan prinsip zero waste,” undergraduate thesis, Universitas Islam Negeri Walisongo Semarang, Semarang, Indonesia, 2022.
[8] W. Sulistiyowati and C. C. Astuti, Buku Ajar Statistika Dasar. Sidoarjo, Indonesia: UMSIDA Press, 2017, doi: 10.21070/2017/978-979-3401-73-7. [9] T. Nurmar’atin, “Deteksi kadar kolesterol dalam darah secara non-invasive menggunakan sistem telemedika berbasis IoT,” undergraduate thesis, Universitas Islam Negeri Walisongo Semarang, Semarang, Indonesia, 2021.
[10] D. R. Tisna and T. Maharani, “Penerapan digital moving average filter pada sensor dissolved oksigen untuk mengukur kualitas air,” Journal of Electrical, Electronic, Mechanical, Informatic and Social Applied Science, vol. 1, no. 2, pp. 32–40, 2022, doi: 10.58991/eemisas.v1i2.13.
[11] Sugiyono, Metode Penelitian Kuantitatif, Kualitatif dan R&D. Bandung, Indonesia: Alfabeta, 2013.





