ANALISIS KELAYAKAN ELEVATOR STUDI KASUS HOTEL GRAND TJOKRO DAN MATARAM CITY YOGYAKARTA
DOI:
https://doi.org/10.21831/inersia.v10i2.9966Abstract
The purpose of the study ist o e x ami n e e l e v a t o r p a s s e n g g e r f o r Ho t e l GrandTjokro Yogyakarta (HGTY) building and Apartment and Hotel Mataram Yogyakarta rewards to
elevator requirement as a condition of a residential building needs in terms of capacity, speed
and amount. The approach of the study was case study. This study conducted by collecting
building data (builds drawing) and specifications of the building elevators. The Analysis
elevators using 2 references plan, which are taken from the table chart of Benjamin Stein in the
book Mechanical And Electrical Equipment for Building (MEE) and the empirical way of Hartono
Purbo (2007). Based on the analysis of table sandgraphsof MEE, the result of the study showed
that HGTY requires 2 lifts (1050 kg, 2 m/s), as well as to AHMCY needs 4 lifts (1000kg, 1.75
m/s). While empirical manner indicates that HGTY need 3 lifts (1050kg, 0.63 m/s) and 2 lifts if
the speed of 2m/s, as well as for AHMCY, elevators analysis is made of 1 zone system and 2
zone system. The system needs to lift 1 zone as much as 2 pieces lifts for apartments and 3
pieces lifts to the hotel, and for the 2 zone system each require 4 lifts (1000kg, 1.75 m/s). Based
on the MEE concluded that (1a) HGTY elevators, speed meets there quirements, but the
numbers cannot be analyzed, because speed does not fulfill the requirements for residential
buildings. As for the (1b) AHMCY elevators, speed and capacity have fulfilled the requirements,
but the number was not sufficient to fulfill there quirements. Based on empirical way concluded
that (2a) HGTY elevators have fulfilled there quirements interms of capacity and speed, but the
number was not sufficient to fulfill the requirements, while for (2b) AHMCY elevators, speed,
capacity and quantity to fulfill the requirement soft the system when made 1 zone, but the
number was not sufficient to fulfill the requirements when made 2 zone system.
Keywords: feasibility, multi-storey buildings, passenger elevators
Downloads
How to Cite
Sumardjito, A. S. (2016). ANALISIS KELAYAKAN ELEVATOR STUDI KASUS HOTEL GRAND TJOKRO DAN MATARAM CITY YOGYAKARTA. Inersia : Jurnal Teknik Sipil Dan Arsitektur, 10(2). https://doi.org/10.21831/inersia.v10i2.9966
Issue
Section
Articles
License
Authors who publish with INERSIA journal agree to the following terms:
- Authors retain copyright and grant the INERSIA journal right of first publication with the work simultaneously licensed under Creative Commons Attribution License (CC BY 4.0) that allows others to share the work with an acknowledgment of the work's authorship and initial publication in this journal.
- Authors can enter into separate, additional contractual arrangements for the non-exclusive distribution of the published version of the work (e.g., post it to an institutional repository or edit it in a book), with an acknowledgment of its initial publication in this journal.
- Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) before and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work.

INERSIA by https://journal.uny.ac.id/index.php/inersia was distributed under a Creative Commons Attribution 4.0 International License