Pengaruh sistem pengaplikasian automatic generation control (AGC) terhadap sistem ketenagalistrikan
Arif Nur Afandi, Universitas Negeri Malang
Abstract
Implementing Automatic Generation Control (AGC) activation in the Java Madura Bali system is one of PLN's Anti Black Out breakthrough programs in the context of strengthening defense to prevent widespread blackouts due to disturbances. The existing Load Frequency Control (LFC) system at the Tambak Lorok PLTGU has not been operating for a long time, so it was chosen to implement the activation of the AGC system which will be controlled automatically by the Dispatcher Java Control Center (JCC) through the SCADA system control scheme. When testing real-time loading, the frequency of the Java-Bali system is conditioned to be at 50,154 Hz and 49,819 Hz. The data is used as a reference for the successful implementation of AGC activation for other PLTGUs in the hope that other PLTGUs can immediately contribute to the AGC system. With fast AGC activation, the purpose of system operation will be achieved better, and the quality of the Java Madura Bali electrical system frequency will be maintained at 50 Hz. AGC is also a solution to the future challenges of intermittent renewable energy.
Keywords
References
Peraturan Menteri ESDM Republik Indonesia, Aturan Jaringan Sistem Tenaga Listrik, Jakarta: Kementrian ESDM, 2020.
P. Kundur, Power System Stability and Control, California: McGraw-Hill, Inc., 1993.
R. S. Lubis, “Penerapan Kendali Optimal pada Automatic Generation Control (AGC) Meliputi Eksitasi dalam Sistem Multi-Area,” Rekayasa Elektrika, 2009.
Siemens, Power System Control Sinaut Spectrum, 1st Edition Release 4.3, 1988.
Sub Bidang Analisa dan Evaluasi Operasi Sistem, Buku Evaluasi Operasi Tahunan (EOT) Sistem Jawa Madura Bali 2021, Jakarta: PT PLN (Persero) Unit Induk Pusat Pengatur Beban, 2021.
D. Marsudi, Operasi Sistem Tenaga Listrik, Yogyakarta: Graha Ilmu, 2016.
D. Y. Istiqomah dan A. Triwiyatno, “Analisa Indeks Kekuatan Sistem untuk Penggunaan Load Frequency Control (LFC) pada Fungsi SCADA di PT PLN (Persero) P3BJB dengan Mengamati Respon Daya Generator PLTA Cirata Unit 2,” Seminar Kerja Praktik, 2014.
N. Li, L. Chen, C. Zhao dan S. H. Low, “Connecting Automatic Generation Control and Economic Dispatch from an Optimization View”.
A. Narvaez, “Implementation and Tuning of the Automatic Generation Control in the Energy National Control Center of Ecuador - CENACE,” IEEE, 2005.
B. Panjaitan, Teknologi Sistem Pengandalian Tenaga Listrik Berbasis SCADA, Jakarta: Prenhallindo, 1999.
I. Rasyidi dan I. Robandi, “Perencanaan Sistem AGC (Automatic Generation Control) Pada Sistem Tenaga Listrik Multi Area”.
E. Yawantoro, B. Suprandono dan A. Solichan, “Analisa Keandalan Sistem Tenaga Listrik Jawa Tengah dan DIY Periode Tahun 2009-2011,” Media Elektrika, 2012.
DOI: https://doi.org/10.21831/jps.v30i1.68493
Refbacks
- There are currently no refbacks.
Copyright (c) 2025 Jurnal Penelitian Saintek

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.
p-ISSN: 1412-3991 || e-ISSN: 2528-7036
Indexed by:
View My Stats