INVESTIGASI TEGANGAN LEBIH TRANSIEN AKIBAT SAMBARAN PETIR PADA GARDU INDUK 150 KV
Abstract
ABSTRACT:
Electrical energy is the essential things that we need in any aspect of the like industry, hospital, school, etc. Therefore, the transmission of electrical power has to be reliable and continuous. However, those ideal condition is hard to achieve in daily basis because if disruption like lightning impulse. Arrester is a device that prevents or stops overvoltage disruption. In this research, two kinds of arrester are compared and modeling substation devices using simulation software ATPDraw. The simulation result shows us that the Q150NA121A arrester has outstanding performance with an overvoltage value of 454 kV. In the other side, Q150NB121A arrester has overvoltage value at 579 kV.
ABSTRAK:
Energi listrik merupakan kebutuhan yang sangat penting pada setiap sektor seperti pendidikan, industri, rumah sakit, dan lain-lain. Oleh sebab itu penyaluran energi listrik diharapkan memiliki kontinyuitas dan kehandalan yang tinggi, namun dalam praktiknya hal tersebut sulit tercapai disebabkan karena berbagai macam gangguan salah satunya gangguan tegangan lebih impuls petir. Arester adalah peralatan yang saat ini banyak digunakan secara luas untuk mengurangi dan mencegah gangguan tegangan lebih. Pada penelitian ini dua tipe arester dibandingkan serta memodelkan peralatan yang ada pada gardu induk dengan menggunakan simulasi ATPDraw. Hasil simulasi menunjukkan bahwa arester tipe Q150NA121A mempunyai kinerja yang sangat baik dengan nilai tegangan lebih sebesar 454 kV. Sedangkan untuk arester tipe Q150NB121A nilai tegangan lebih sebesar 579 kV.
Keywords
Full Text:
PDFReferences
IEEE Std C62.22a, 2013. IEEE Guide for the Application of Metal-Oxide Surge Arresters for Alternating-Current Systems. IEEE.
I. W. G. 3.4.11. 1992. Protective Devices Committee’s subcommittee. Trans. Power Deliv., vol. 7, no. 1, pp. 302–309.
J. Sardi, J. Ong, and C. Chian. 2010. “Evaluation of Surge Arrester Requirement for Overhead Transmission Line using Electromagnetic Transient Program,” IEEE Int. Conf. Power Energy, pp. 985–988.
M. B. Nappu, A. Arief, and S. M. Said. 2018. The Placement of the Transmission Lightning Arrester ( TLA ) at 150 kV Network using Fuzzy Logic. pp. 347–352.
S. A. Ali. 2013. Design of lightning arresters for electrical power systems protection. Adv. Electr. Electron. Eng. vol. 11, no. 6, pp. 433–442, doi: 10.15598/aeee.v11i6.661.
S. A. Hosseini, M. Mirzaie, and T. Barforoshi. 2015. Impact of Surge Arrester Number and Placement on Reliability and Lightning Overvoltage Level in High Voltage Substations. Int. J. Electr. Power Energy Syst., vol. 65, pp. 146–158, doi: 10.1016/j.ijepes.2014.09.037.
DOI: https://doi.org/10.21831/jee.v5i1.39315
Refbacks
- There are currently no refbacks.
Copyright (c) 2021 Jurnal Edukasi Elektro
This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.
Indexed by:
Supported by:
JURNAL EDUKASI ELEKTRO by Jurusan Pendidikan Teknik Elektro, Fakultas Teknik UNY distributed under a Creative Commons Attribution 4.0 International License based on the copyright of https://journal.uny.ac.id/index.php/jee/.